24-Hour or 7-Day 12/24 VDC, 24 VAC Electronic Panel Mount Module, 15 A, 50 Setpoint Programs, SPDT
Model#FM1D50-LV
24-Hour or 7-Day 12/24 VDC, 24 VAC Electronic Panel Mount Module, 15 A, 50 Setpoint Programs, SPDT
Model#FM1D50-LV
- 24-Hour, 7-day or cycle timer applications.
- 50 Setpoint programs.
- Easy to program.
- Manual override with status indication.
- Self-recharging battery with backup protection up to 2500-hours.
- LCD display.
- Cycle timer function.
- Aeration
- Air Movement & Ventilation
- Generator Exercising
- Refrigeration Merchandiser
- Septic Treatment
Backup Type Battery Color White Mechanism Type Digital/Electrical Mounting Options Panel Number Of Circuits 1 Operation Mode 24 hour, 7-day, Cycle Switch Type SPDT Minimum ON/OFF Times 1 min Maximum ON/OFF Times 23 hours, 59 minutes Maximum Power Consumption (W) 1.4 W Wiring Option Spade terminals for #24 to #10 AWG wire (A models) Backup Protection Time 2500 Hours ON/OFF Operations 50 Warranty Period 1-Year limited Application Compatibilities LED Battery Service Type Self-recharging CAProp65Message This product is in compliance with Prop65 Country Of Origin China Daylight Savings Adjustment Manual Electronic Ballast (NO) 4.9 A, 120 VAC Electronic Ballast Load Ratings NO Ranges 4.9 A, 120 VAC General Purpose (NC) 15 A, 277 VAC General Purpose (NC) Range(s) 15 A, 277 VAC General Purpose (NO) 15 A, 277 VAC General Purpose (NO) Range(s) 15 A, 277 VAC Has Clear Dust Cover Yes Has Manual Override Status Indication Yes Magnetic Ballast (NC) 8 A, 120 VAC Magnetic Ballast (NC) Range(s) 8 A, 277 VAC Magnetic Ballast (NO) 8 A, 277 VAC Magnetic Ballast (NO) Range(s) 8 A, 277 VAC Material Noryl Motor Load Ratings NC Ranges 1/2 HP @ 120/240 VAC; 10 FLA, 60 LRA @ 250 VAC Motor Load Ratings NO Ranges 1/2 HP @ 120 VAC; 10 FLA, 60 LRA @ 250 VAC; 1 HP @ 250 VAC Operating Humidity 0-95% RH, Non-condensing Pilot Duty (NO) B300 Pilot Duty (NO) Range(s) B300 Resistive (NC) Range(s) 15 A, 277 VAC Resistive (NO) Range(s) 15 A, 277 VAC RoHS Certification Y Tungsten (NO) Load Ratings 1000 W, 120 VAC Tungsten (NO) Range(s) 8 A, 277 VAC Voltage Selection Type Voltage Specific Wire Size Max #10 AWG Wire Size Min #24 AWG Auto Start/Stop False Check Valve False DOE Compliant False Freeze protection False Leaf Screen False Operating Temperature Max (°C) 55 Operating Temperature Max (°F) 131 Operating Temperature Min (°C) -15 Operating Temperature Min (°F) 5 Product Depth (in) 0.83 Product Depth (mm) 21.082 Product Height (in) 2.36 Product Height (mm) 59.944 Product Width (in) 2.36 Product Width (mm) 59.944 Self Priming False Submersible False UL Certification CULUS Unit Carton Height (in) 1.25 Unit Carton Length (in) 2.375 Unit Carton Weight (lb) 0.1 Unit Carton Width (in) 2.375 Units Per Pallet 1596 UV Resiliant Outdoor Enclosure False